tidy3d.SteadyChargeDCAnalysis#
- class SteadyChargeDCAnalysis[source]#
Bases:
Tidy3dBaseModelConfigures relevant steady-state DC simulation parameters for a charge simulation.
- Parameters:
tolerance_settings (
ChargeToleranceSpec= ChargeToleranceSpec()) – Charge tolerance parameters relevant to multiple simulation analysis types.convergence_dv (PositiveFloat = 1.0) – By default, a solution is computed at 0 bias. If a bias different than 0 is requested through a voltage source, the charge solver will start at 0 and increase bias at convergence_dv intervals until the required bias is reached. This is, therefore, a convergence parameter in DC computations.
fermi_dirac (bool = False) – Determines whether Fermi-Dirac statistics are used. When
False, Boltzmann statistics will be used. This can provide more accurate results in situations where very high doping may lead the pseudo-Fermi energy level to approach either the conduction or valence energy bands.
Attributes
- tolerance_settings#
- convergence_dv#
- fermi_dirac#