This class defines standard SPICE electrical_analysis types (electrical simulations configurations).
"""
from __future__ import annotations
from pydantic import Field, PositiveFloat, PositiveInt, model_validator
from tidy3d.components.base import Tidy3dBaseModel
from tidy3d.constants import KELVIN
from tidy3d.log import log
[docs]
class ChargeToleranceSpec(Tidy3dBaseModel):
"""
Charge tolerance parameters relevant to multiple simulation analysis types.
Example
-------
>>> import tidy3d as td
>>> charge_settings = td.ChargeToleranceSpec()
"""
abs_tol: PositiveFloat = Field(
default=1e10,
title="Absolute tolerance.",
description="Absolute tolerance used as stop criteria when converging towards a solution. "
"This is honored by the legacy solver only; on the accelerated (default) solver, "
"``rel_tol`` is the effective convergence criterion.",
)
rel_tol: PositiveFloat = Field(
default=1e-10,
title="Relative tolerance.",
description="Relative tolerance used as stop criteria when converging towards a solution.",
)
max_iters: PositiveInt = Field(
default=120,
title="Maximum number of iterations.",
description="Indicates the maximum number of iterations to be run. "
"The solver will stop either when this maximum of iterations is met "
"or when the tolerance criteria has been met.",
)
ramp_up_iters: PositiveInt = Field(
default=1,
title="Ramp-up iterations.",
description="In order to help in start up, quantities such as doping "
"are ramped up until they reach their specified value. This parameter "
"determines how many of this iterations it takes to reach full values.",
)
max_pseudo_steps: PositiveInt = Field(
default=60,
title="Maximum pseudo steps.",
description="Maximum number of pseudo time steps used per physical step "
"in the drift-diffusion solver.",
)
cfl_number: PositiveFloat = Field(
default=1e9,
title="CFL number.",
description="CFL multiplier used in the drift-diffusion solver. "
"Controls the pseudo time step size and acts as the upper bound "
"of the adaptive CFL controller.",
)
cfl_min: PositiveFloat | None = Field(
default=None,
title="Minimum CFL number.",
description="Lower bound of the adaptive CFL controller in the drift-diffusion "
"solver. When ``None`` (default), the solver uses ``cfl_number * 1e-6`` so "
"behaviour matches setups that predate this field. Setting ``cfl_min`` equal "
"to ``cfl_number`` effectively runs the solver with a constant CFL (no "
"adaptive backoff).",
)
preconditioner_iterations: PositiveInt = Field(
default=50,
title="Preconditioner iterations.",
description="Maximum number of preconditioner iterations in "
"the linear solver of the drift-diffusion solver.",
)
@model_validator(mode="after")
def _warn_non_default_solver_params(self) -> ChargeToleranceSpec:
"""Warn when solver parameters differ from their defaults."""
field_names = (
"max_pseudo_steps",
"cfl_number",
"cfl_min",
"preconditioner_iterations",
)
fields = type(self).model_fields
changed = [name for name in field_names if getattr(self, name) != fields[name].default]
if changed:
log.warning(
f"Non-default values detected for {', '.join(changed)} in "
"'ChargeToleranceSpec'. Settings different than the defaults can lead to "
"long simulation times, lack of convergence, and divergence."
)
return self
@model_validator(mode="after")
def _warn_cfl_min_above_max(self) -> ChargeToleranceSpec:
"""Warn when ``cfl_min`` exceeds ``cfl_number`` (the adaptive-CFL upper bound)."""
if self.cfl_min is not None and self.cfl_min > self.cfl_number:
log.warning(
f"'cfl_min' ({self.cfl_min}) is greater than 'cfl_number' "
f"({self.cfl_number}) in 'ChargeToleranceSpec'. The adaptive CFL "
"controller expects cfl_min <= cfl_number; with these bounds "
"inverted the controller will clamp to the (smaller) upper bound "
"every step and the solver may not behave as intended."
)
return self
[docs]
class SteadyChargeDCAnalysis(Tidy3dBaseModel):
"""
Configures relevant steady-state DC simulation parameters for a charge simulation.
"""
tolerance_settings: ChargeToleranceSpec = Field(
default=ChargeToleranceSpec(),
title="Tolerance settings",
description="Charge tolerance parameters relevant to multiple simulation analysis types.",
)
convergence_dv: PositiveFloat = Field(
default=1.0,
title="Bias step.",
description="Maximum bias step used to aid convergence in DC computations. "
"The accelerated solver applies it only to multi-voltage sweeps: where the gap "
"between consecutive sweep voltages exceeds `convergence_dv`, intermediate "
"warm-start bias points are inserted (and excluded from the output); a "
"single-voltage simulation is solved directly. The legacy solver instead ramps "
"every requested bias from 0 in `convergence_dv` increments.",
)
fermi_dirac: bool = Field(
False,
title="Fermi-Dirac statistics",
description="Determines whether Fermi-Dirac statistics are used. When ``False``, "
"Boltzmann statistics will be used. This can provide more accurate results in situations "
"where very high doping may lead the pseudo-Fermi energy level to approach "
"either the conduction or valence energy bands.",
)
[docs]
class IsothermalSteadyChargeDCAnalysis(SteadyChargeDCAnalysis):
"""
Configures relevant Isothermal steady-state DC simulation parameters for a charge simulation.
"""
temperature: PositiveFloat = Field(
300,
title="Temperature",
description="Lattice temperature. Assumed constant throughout the device. "
"Carriers are assumed to be at thermodynamic equilibrium with the lattice.",
json_schema_extra={"units": KELVIN},
)